EnergyWar.net

Operational failure

Communications Facility

Telstra Triple Zero call centre — transfer-system disruption

1 March 2024 · 90 minutes

Australia (national emergency-call service)

-35.2800, 149.1300

Preparing your incident map…Loading the basemap and incident layers

What happened

A technical disruption hampered Telstra's national Triple Zero call centre for 90 minutes. An outdated backup-number list meant 127 calls were not transferred normally; details were instead relayed to emergency services by email and phone, while another 346 calls were transferred without digital location information. ACMA found 473 breaches and Telstra paid a penalty exceeding A$3 million.

When cited sources give different casualty, damage or spill figures for this event, they’re reported side by side above rather than merged into one number. See how confidence levels work.

Evidence
Documented
Confidence
High
Infrastructure
Communications Facility
Weather context
Loading…
Latitude
-35.2800°
Longitude
149.1300°

Attribution

Responsibility has not been established in the cited reporting.

Sources

  1. Telstra pays $3 million penalty for Triple Zero outageAustralian Communications and Media Authority · Incident reporting